Please use this identifier to cite or link to this item:
http://ir.lib.seu.ac.lk/handle/123456789/3500
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Raafi, M. A. C. M. | - |
dc.date.accessioned | 2019-03-26T04:34:32Z | - |
dc.date.available | 2019-03-26T04:34:32Z | - |
dc.date.issued | 2018-10-15 | - |
dc.identifier.isbn | 9789556271362 | - |
dc.identifier.uri | http://ir.lib.seu.ac.lk/handle/123456789/3500 | - |
dc.description.abstract | Clinical errors are relatively common in operating theatres (OT) and severely impact on patient health as well as increased medical costs for the healthcare sector. It has beenidentified that it is important to operate a suitable activity detection system in OT to detect physical behaviours of a clinician to prevent error in clinical work. However, the existing technological approaches for activity detection in OT are limited in their ability to detect those physical behaviours and thereby correct the mistakes during clinical work. Therefore,the present study was focused on designing a system model which allows a computer to automatically identify the physical actions of clinicians in order to detect and understand mistakes in the OT to minimize clinical errors. It involves finding suitable technologies to identify activities in the OT and designing a prototype system (PS) to detect activities for an aspect of clinical work. During this research a simulation study was carried out to develop such a PS in order to identify specific physical characteristics in clinical work as a proof of concept. In the simulation study, a volunteer acted as an anaesthetist to perform actions of an aspect of anaesthesia work in a motion capture lab. The movements of volunteer were recorded using motion capture method. The captured data were then used by the developed PS to recognize the activities. The experimental results show that the PS identifies the expected physical activities of the volunteers in that given scenario. It reveals that the developed PS works to detect given physical behaviours in that clinical work. However, the PS was implemented and tested for a small scale task, therefore the other scale tasks would also be considered to upgrade and validate the system in the future research | en_US |
dc.language.iso | en_US | en_US |
dc.publisher | Faculty of Applied Science, South Eastern University of Sri Lanka | en_US |
dc.relation.ispartofseries | Abstracts of the 7th Annual Science Research Sessions (ASRS) – 2018;15 | - |
dc.subject | Activity detection | en_US |
dc.subject | Agent model | en_US |
dc.subject | Anaesthetist | en_US |
dc.subject | Clinical errors | en_US |
dc.subject | Sensor system | en_US |
dc.title | Towards automatic detection of physical activities in clinical works | en_US |
dc.type | Article | en_US |
Appears in Collections: | ASRS - FAS 2018 |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ASRS 2018-15.pdf | 191.11 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.